Activation of DNA Damage Signaling Components by Diagnostic Computed Tomography (CT) Scans Detected in Patient Samples Using an Electrochemiluminescence-Based Assay Platform

Hseih, Yiching and Begley, Ulrike and Endres, Lauren and Keith, James and Hansen, Antonietta F. and Kaminsky, Laurence and McCandless, Brian and Begley, Thomas J. (2017) Activation of DNA Damage Signaling Components by Diagnostic Computed Tomography (CT) Scans Detected in Patient Samples Using an Electrochemiluminescence-Based Assay Platform. Advances in Bioscience and Biotechnology, 08 (07). pp. 228-247. ISSN 2156-8456

[thumbnail of ABB_2017072615511289.pdf] Text
ABB_2017072615511289.pdf - Published Version

Download (1MB)

Abstract

Technologies that measure activation of components of the DNA damage response (DDR) have applications in exposure assessment and personalized medicine. The DDR and associated DNA repair pathways encompass hundreds of proteins, making detailed measurement of activation technically challenging and laborious. The purpose of our study was to develop protein-specific assays for certain DDR components on a high-throughput electrochemiluminescence (ECL)-based platform. We developed five working assay pairs for ataxia telangiectasia mutated (ATM), checkpoint kinase 2 (CHK2), phosphorylated-ATM S1981, phosphorylated-CHK2 T68 and phosphorylated-tumor protein p53 (p53) S15. We validated the ECL results against traditional immunoblot and γ-H2AX foci measures in cell and cancer models. In an effort to test the ECL-based technology in a clinical setting, we utilized peripheral blood mononuclear cells (PBMCs) from patients undergoing computed tomography (CT) scans. CT scans represent both a valuable medical imaging diagnostic and a controlled environmental exposure to ionizing radiation for research studies, as they deliver ~2 to 31 millisieverts (mSv) and are known to activate DDR components. In this study, we show that ECL-based technology can measure the basal and damage-induced levels of DDR components in patient PBMC samples. Using a blinded study design and patient matched pre- and post CT scan samples, we show that ECL-derived data can consistently (94% of the time, 15/16 patients) identify PBMCs that have been exposed to low dose ionizing radiation associated with CT scans. Ultimately, the results of our pilot clinical study support the idea that ECL-based technology is applicable for use in clinical and population cohorts that study components of the DDR.

Item Type: Article
Subjects: Scholar Eprints > Biological Science
Depositing User: Managing Editor
Date Deposited: 25 Feb 2023 07:29
Last Modified: 28 Oct 2024 08:09
URI: http://repository.stmscientificarchives.com/id/eprint/1088

Actions (login required)

View Item
View Item